Navigate to the home page
Увеличить изображение
Linear stage
РУС | ENG

::  MIM-330: Specification

Description Specification Brochure Features Application Image gallery

General specification

   White light navigation channel  Laser channel
 Operating principle
 Digital white light microscope  Laser Modulation Interference Microscope
 Destination  Searching of Region of interest
Measurement of relief and optical properties
 Optical multiplication  100 х
 1000 х
 Field of view
 83 х 83 um
7.3 х 7.3 um
 Travel range of sample stage (XY) 25 х 25 mm 25 х 25 mm
Travel range of sample stage vertical (Z)  10 mm
 10 mm
 Discretization interval (XY plane)
85 nm
 7 nm
 Discretization interval vertical (Z)
 -  0,01 nm
 Vertical resolution (Z)
 -  0,1 nm
 Lateral optical resolution (XY plane)  0,5 um
 100 - 15 nm (Object depended)
Depth of relief, maximum
 730 nm
 200 - 600 nm (Object depended)
 Sensor array
 1280 х 1024 pixels  1024 х 1024 pixels
 Acquisition time  30 frames in second
 3 - 30 frames in second (depends on ROI size)
 Flange focal distance
 1 mm
1 mm
 Step of focusing
 100 nm
100 nm
 Speed of focusing  10 um/s 10 um/s

Light source specification:


White light navigation channel Laser channel
Type of source
 Light emission diode  Laser
 Wave length
 White
 405 nm
 Power  -  20 mW

Polarization characteristics of MIM-330

 Type of polarisation
 Linear, elliptic
 Degree of polarization
100 : 1
 Angle of inclination of polarization ellipse
 0° - 360°
 Step  3.6° ± 0,1°
 Ellipticity  - 1 ... 1

Software

 Software for operation and measurement
MIMSoft-3
 Software for measuring data processing  MIM Visualiser

Additionally

 Auto focus         •         
Polarization control         •         
 Nano-dynamics registration
        •         
 Panoramic acquisition mode
        •         
 Stitching mode
        •         
 Motorized sample stage
 Active vibration isolation system
        •         

Size of samples

 Maximum size of sample
 ø 100 mm
 Maximum thickness of sample (down stage position)
 20 mm to a objective
 Maximum thickness of sample (upper stage position)
 5 mm to a objective
 Maximum weight of sample  15 kg

Power requirements

 Source  Power adapter of control computer
 Power consumption
 30 W

Environmental condition

 Type of room  Laboratory, heated, dry-type
 Operating-temperature range
  from - 15° to + 30° С
 Air moisture
 < 80%

Control computer minimal system requirements

 CPU  Pentium 4
 CPU frequency  2 GHz
 RW memory  512 Mb
 Video display board
+
 HDD space  100 Mb
 Operation system  Windows XP and upper

Dimension

 Length, mm
 275
 Wide, mm
 405
 High, mm
 540
© 2010 AMPHORA Laboratories
разработка сайтов - SilverSite.ru